Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | TOKEN |
Model Number : | TBC-DHS3.3 |
Certification : | CE;ROHS |
Price : | Price Reconsideration |
Supply Ability : | 2.2K pcs per month |
Hall Current Transducer Closed Loop Hall Effect Current Sensor AC
DC
TBC-DHS3.3 series multi-range current sensor is a closed loop
device based on the measuring principle of the hall effect and null
balance method, with a galvanic isolation between primary and
secondary circuit. It provides accurate electronic measurement of
DC, AC or pulsed currents.
Electrical data(Ta=25℃±5℃) |
Type Parameter | TBC06DHS3.3 | TBC15DHS3.3 | TBC25DHS3.3 | TBC50DHS3.3 |
|
Rated input (Ipn) | 6 | 15 | 25 | 50 | A |
Measure range(Ip) | ±12 | ±30 | ±50 | ±100 | A |
Secondary turns(Ns) | 1152±1 | 1440±1 | 1200±1 | 1200±1 | T |
Internal resister | 30±0.1% | 15±0.1% | 7.5±0.1% | 3.75±0.1% | Ω |
Rated output (Vsn ) | Ip=±Ipn ±0.625±0.5% | V | |||
Supply voltage | +3.3±5% | V | |||
Power consumption | ≤15+Ip/Ns | mA | |||
Zero voltage | @ Ip=0 1.65±0.5% | V | |||
Zero voltage drift | @ -40~+105℃ ≤±0.05 | mV/℃ | |||
output drift | @ -40~+105℃ ≤±0.05 | mV/℃ | |||
Linearity | @ Ip=0-±Ipn ≤ 0.1 | %FS | |||
Total precision | ≤±0.7 | % | |||
di/dt accurately followed | >50 | A/µS | |||
Response time | @ Ip=Ipn, 50 A/µS ,10%-90% <500 | nS | |||
Bandwidth | @ -1db DC~200 | KHZ | |||
Galvanic isolation | @ 50HZ,AC,1min 2.5 | KV |
Applications |
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies(SMPS)
Power supplies for welding applications
Solar inverters
Mechanical dimension(for reference only) |
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
Pin connections |
Turns | Rated current | Rated output | Primary impedance | Primary inductance | Connected points |
1 | ±6(±15, ±25,±50) | 1.65±0.625 | 0.18 | 0.013 | ![]() |
2 | ±3(±7.5, ±12.5,±25) | 1.65±0.625 | 0.81 | 0.05 | ![]() |
3 | ±2(±5, ±8.3,±16.6) | 1.65±0.625 | 1.62 | 0.12 | ![]() |
Directions for use |
When the current will be measured goes through a sensor, the
voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
Custom design in the different rated input current and the output
voltage are available.
Standards |
General date |
Value | Unit | Symbol | |
Operating temperature | -40 to +105 | ºC | TA |
Storage temperature | -40 to +125 | ºC | TS |
Mass(approx) | 10 | g | M |
Characteristics chart |
Pulse current signal response characteristic Effects of impulse
noise
![]() |